1 CRIB Magnets information
2 ========================
4 The following is the information on the magnets in CRIB.
6 To be more precise, CRIB has higher order components
7 for some historical reason.
8 However, we usually have a satisfactory result by
9 the first-order calculation.
15 L1=0.077 ; Q1 effective field fength- pole length, unit is m
17 DL(Drift length): 0.32-L1/2
23 D1: horizontal half aparture: 10.0 cm
24 entrance face angle -13.553 deg.
26 entrance face curvature 2.2727 m-1
28 First part: angle=-25.0 deg, L=0.3927
29 Second part: angle=70.0 deg, L=1.0996
31 exit face angle -20.0 deg.
32 exit face curvature -1.6393 m^-1
47 D2: horizontal half aparture: 10.0 cm
48 entrance face angle -25.185 deg.
50 entrance face curvature 0.0 m-1
52 First part: angle=-60.0 deg, L=0.9425
53 Second part: angle=-30.0 deg, L=0.4712
55 exit face angle -7.187 deg.
56 exit face curvature -1.6949 m^-1
62 M3: L=0.2+LM3 (Quadrupole)
72 [F2;R16=0,R12=0,R34=0]
89 [WF center; R22=0,R34=0]
91 electrode distance: 80mm
103 DL: 0.5165-L4/2 + 0.013
107 DL: 0.700 (<- depends on the setup)
109 [F3 target position; R12=0,R34=0]
130 WF: electrode distance: 80mm
131 max voltage 200kV (stable at ~100kV)
132 max magnetic field 0.3T
146 Q2 V 30mm H: wide (~400mm)