🔗 http://www.cns.s.u-tokyo.ac.jp/~lim/elog/doku.php?id=2026-02_kek:10
| Subject: Circuit breaker down | Type: Error/Fault | Category: General | Tags: None |
Circuit breaker down
The second circuit breaker was down due to the current limit: 15 A
The reason was that all of oscilloscopes are connected in one power tap (maximum 15 A current with 100V = 1500W).
Estimated power consumption from 6 oscciloscopes is around 3kW.
The power tap was down after the scope is about to boot (windows → scope software), so I expect the power consumption became a peak at that time.
As a result, the fuse in the power tap was burned.
We called PF-AR organizer (Ext. 2493) and took the photo → we should calculate the total power consumption well and distribute considering the current limit.